Mallam Accra Ghana MGPCITYPLAN 2 1024x512Geothermal in the Heat Sequence

Why ground and mine-water heat should be planned alongside Fabric First and the heat pump rollout, and what that means for UK heat zoning.

Summary

  1. On 29 October 2026 the European Geothermal Energy Council (EGEC) asked EU energy ministers for a target of at least 250 GW of geothermal capacity across heat, cooling and power by 2040, up from 41.4 GW today.
  2. For buildings, the question is less "heat pump or not" than where the heat comes from: outdoor air, the ground, mine water, or a shared network. That choice decides how hard the electricity system is pushed on the coldest days.
  3. Fabric First and geothermal reinforce each other. Lower heat demand means fewer borehole metres and lower flow temperatures; ground and network sources then turn that lower demand into a lower winter grid peak.
  4. Uncoordinated, house-by-house air-source installation risks locking streets out of shared ground loops and heat networks for a generation. England's new heat network zoning is the natural place to prevent this, if its scope is widened.

The prompt: EGEC's 250 GW proposal

EGEC timed its call to the Luxembourg meeting of EU energy ministers on energy security and the post-2030 framework. It wants a geothermal-specific target written into the Action Plan of the European Geothermal Stakeholder Partnership announced under the Commission's Electrification Action Plan (17 July 2026), and progress tracked through the forthcoming Energy Union governance regulation that will replace Regulation (EU) 2018/1999.

EGEC estimates that 250 GW would yield over 1,000 TWh a year, about a fifth of projected EU final energy use outside transport in 2040. Its argument is framed around security and sovereignty: home-grown heat and power at stable prices, rather than a repeat of past crisis responses. The full proposal is in EGEC's 2040 target paper, building on its December 2025 strategy and action plan proposals.

The heat sequence

Our earlier work argued that heat policy has skipped a step: installing heat pumps before reducing the heat demand they must meet. Geothermal adds a second link to that chain. The order matters because each step changes the economics of the next.

  1. Fabric First – Insulation, airtightness and glazing cut peak and annual heat demand.
  2. Lower flow temperature – Emitters can run at 35–45 °C; low-temperature and ambient networks become viable.
  3. Smaller ground array – Borehole length scales with load, so drilling, usually the largest capital item, falls.
  4. Lower winter grid peak – A source at a stable 10–15 °C keeps efficiency high when outdoor air is coldest.

Read backwards, the chain is the case for funding fabric: every kilowatt of peak demand removed is borehole metres not drilled and grid capacity not built.

What the UK field data shows

Measured performance in British homes supports the source argument, with caveats about sample sizes and installation quality.

Study

Finding

Figure

Electrification of Heat demonstration (742 homes)

Median seasonal performance factor, air-source (SPF H4)

2.80

In-situ analysis of Ofgem RHI data, 2017–22 (1,700+ systems)

Share reaching SPF 3.0 or above

GSHP >50% · ASHP ~25%

Same dataset

Share reaching SPF 3.5 or above

GSHP 33% · ASHP 8%

Sources: Energy Systems Catapult, EoH performance data; rb&m for DESNZ, RECC and GSHPA, In-situ heat pump performance. The EoH trial had too few ground-source systems to draw conclusions on them, and both studies found a gap between design and measured performance.

The point for policy is the winter shape of demand, not the annual average. Annual SPFs understate the difference between sources, because air-source efficiency falls exactly when national demand peaks.

2011images WELTEC Plant2 416453511The lock-in risk, and where zoning comes in

Once most homes on a street have their own air-source unit, too little demand is left to justify a shared ground loop or a heat network. A choice made one boiler replacement at a time can close off the better system for decades.

England now has the tool to prevent this. The Energy Act 2023 gives government powers to designate heat network zones: areas where networks are expected to be the lowest-cost low-carbon option. Government published its response on zoning alongside the Warm Homes Plan in January 2026, with a zoning authority housed first in DESNZ and later in the Warm Homes Agency.

We propose that the same spatial exercise classify every area into one of three heat routes, and that fabric retrofit programmes be scheduled to match:

  • Network zone – Dense demand near a heat source: mine water, sewers, deep geothermal, industrial or data-centre waste heat.
  • Shared ground loop zone – Terraces and estates where street-scale boreholes, owned and financed as infrastructure, serve individual heat pumps.
  • Individual heat pump zone – Dispersed or rural housing where air-source, or a hybrid, is the practical answer.

Geothermal through the IUM lens

Integrated Urban Metabolism treats a city's heat, waste, water and energy flows as one system. Geothermal fits as the stable base load beneath it, and the UK already has a working example.

In Gateshead, the council's energy company draws water at about 15 °C from flooded coal workings 150 m below the town centre and lifts it to 80 °C for its network. The 6 MW scheme runs through 5 km of pipe and serves around 350 homes plus colleges, arts venues and offices, supported by £5.9m of Heat Networks Investment Project funding. Gateshead now hosts a mine water heat living laboratory led by the Mining Remediation Authority, publishing open data.

Many British towns grew on coal, so the same resource lies under many places that will need heat zoning. Combined with sewer heat, waste heat and biomethane-fired CHP from anaerobic digestion, mine water gives an IUM district several local heat sources and a way to keep running when the wider grid is under stress.

Stating the security case honestly

Caveats we should own

  • Shallow geothermal still needs electricity. It needs less than air-source, especially in cold spells, but it is not off-grid. Independence comes from deep geothermal used directly, which needs only pumping power, or from pairing ground systems with local generation such as biomethane CHP.
  • EGEC is a trade body. Growing from 41.4 to 250 GW is about a six-fold increase in 14 years, and much of the counted capacity will be ground-source heat pumps. Its arithmetic holds: 1,000 TWh from 250 GW implies about 4,000 full-load hours a year, demanding but realistic for base-load heat.
  • The UK is outside the EU27. What transfers is the method: a geothermal-specific target, monitored through a governance framework. To our knowledge the UK has no equivalent target.

Recommendations

  1. Size heat pumps after fabric. Public support for heat pumps should require a fabric assessment and size systems to the post-retrofit heat loss, so that ground arrays and networks are not over-built.
  2. Widen heat zoning to three routes. Use the zoning model to designate network, shared ground loop and individual heat pump areas, and schedule retrofit programmes to match.
  3. Map the resource into local plans. Put mine water, aquifer and shallow ground data from the British Geological Survey and the Mining Remediation Authority into Local Area Energy Plans and zone coordinators' work.
  4. Finance shared ground loops as infrastructure. Street-scale boreholes last for decades and should carry long-term, utility-style finance, separate from the household heat pump.
  5. Adopt a UK geothermal target. Follow the EGEC method with a target for heat, cooling and power, reported through UK energy governance.
  6. Pilot it. Urbium Research proposes a coalfield-town demonstrator combining fabric retrofit, a mine-water or shared-loop network and IUM resource integration, with measured winter peak reduction as the headline metric.

Related Urbium work

  • Waste Heat, Wasted Methane: The Case for Integrated Urban Metabolism – The core IUM argument: recovering waste heat and methane as one urban system.
  • URBium Research Ltd: Investment Proposal for the IUM Platform – The research and investment programme this note feeds into.
  • Resilient Heat for Care Homes: The URBium Approach – Applying resilient, local heat to a sector that cannot afford outages.

Sources

  1. EGEC, Geothermal deployment target of 250 GW by 2040 (29 Oct 2026)
  2. EGEC, Proposals for the EU Geothermal Strategy and Action Plan (5 Dec 2025)
  3. European Commission, Electrification Action Plan (17 Jul 2026)
  4. European Commission, Update of the governance of the Energy Union and climate action
  5. UK, Heat network zoning collection
  6. DESNZ, Heat network zoning consultation: summary of government response (Jan 2026)
  7. DESNZ, Heat network zoning: overview of proposals (Jan 2026)
  8. Energy Systems Catapult, Electrification of Heat: heat pump performance data
  9. rb&m, In-situ heat pump performance: analysis of Ofgem data 2017–2022 (2024)
  10. RefIndustry, summary of EoH and in-situ findings (SPF 3.5 shares)
  11. Gateshead Council, Zero carbon power shows the way ahead
  12. UK, Gateshead mine water heat scheme gets official seal of approval (Jan 2024)
  13. Homebuilding & Renovating, Gateshead mine water heat living lab